Teejet IC18 SPRAYER JOB COMPUTER Uživatelský manuál Strana 38

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 68
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 37
32
www.teejet.com
ISOBUS Job Computer : IC18 Sprayer
OVERVIEW SETUP APPENDIXGETTING STARTED OPERATION
Flow Sensor
Figure 3-26: Flow Sensor
The Flow Sensor establishes the pulses per gallon/liter.
This value can be established manually or calibrated
automatically.
Manual Calibration
Manual calibration establishes the calibration and limits
based on user entered values.
To select the Flow Meter Calibration, use the number
pad or slide bar.
To select the Low Limit, use the number pad or slide
bar.
To select the High Limit, use the number pad or slide
bar.
Automatic Calibration
If the number of pulses per gallon/liter for the ow meter is not known or to make sure the value is correct,
automatic calibration establishes the calibration and limits.
To calibrate the ow sensor, select CALIBRATION KEY .
Follow the series of instructions displayed.
Select the ACCEPT KEY to complete the calibration
The pulses counted will be displayed during the automatic calibration.
An option to enter a Collected Volume is displayed if there is no calculated volume.
To enter the Collected Volume, use the number pad or slide bar.
Zobrazit stránku 37
1 2 ... 33 34 35 36 37 38 39 40 41 42 43 ... 67 68

Komentáře k této Příručce

Žádné komentáře