AutoSteer Setup
Icon Description Factory Setting Range User Setting
Autosteer On
Valve Type Standard PWM
Valve Frequency 175 Hz 0.9 - 15000.1 Hz
Minimum Duty Cycle Left 20.0% 0.0 - 50.0%
Minimum Duty Cycle Right 20.0% 0.0 - 50.0%
Maximum Duty Cycle 50% 25 - 100%
Coarse Steering Adjustment 25.0 1.0-100.0
Fine Steering Adjustment 25.0 1.0-100.0
Deadband 1 1-10
Lookahead 4.0 0.0-10.0
Steering Wheel Sensor Magnetic
Angle Sensor Disabled
Tilt Gyro Module Setup
Icon Description Factory Setting Range User Setting
Tilt Correction On/Off Off
Video Setup
Icon Description Factory Setting Range User Setting
Cameras Normal
Data Management
Options
Icon Description Factory Setting Range User Setting
Job Mode Varies depending on release version.