Teejet Legacy 6000 CAN Guide Uživatelský manuál Strana 192

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 194
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 191
B-4
Appendix B - Creating a Calibration Table
Fieldware for The Legacy 6000
Software Version 2.11
Creating a Calibration Table Using the Legacy 6000
From PCM Setup navigate to the Primary Sensor page and select the tools button.
Use the Down arrow to highlight Cal# Basis and press enter.
Name the Cal# Basis, this will be the Name of the Cal Table. Once a name has been estab-
lished continue forward through PCM Setup and apply the settings.
Advance to the ARM Launcher page and select the Calibration button. Choose the calibration
procedure for the application and press the green forward arrow.
Because Cal# Basis is not NONE in PCM Setup, a new screen appears in calibration. This
screen will have the same name that was entered for Cal# Basis in PCM Setup. From this
screen name a parameter to be calibrated. In the example above GATE HEIGHT was the Cal
Table name and each parameter was described in inches (1 INCH, 2 INCH, ...etc.)
Proceed through calibration, once calibrated name the next parameter in the Cal Table and
Calibrate. Repeat this step for each Cal Table parameter.
NOTE: If GATE HEIGHT is used for the Cal# Basis name in PCM Setup, Midwest Technologies
has pre-named the parameters in Calibration 1 INCH - 12 INCH.
Zobrazit stránku 191
1 2 ... 187 188 189 190 191 192 193 194

Komentáře k této Příručce

Žádné komentáře