Teejet Legacy 6000 Manual Uživatelský manuál Strana 154

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 159
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 153
Legacy 6000
98-05053 R2
149
APPENDIX B - CREATING CALIBRATION
TABLE
A Calibration Table can be created two ways. It is recommended that the table be
created on a PC and loaded on the Legacy 6000. The second option is to create
the table using the Legacy 6000. A Calibration Table allows the operator to select
fromapre-denedsetofcalibrationnumbersthatarecommonlyused.Anexample
would be a granular application in which the gate height changes frequently, result-
ing in the change of the calibration number.
Creating a Calibration Table on a PC
Create a calibration table with a text editor (such
asNOTEPAD)andsavetheleas“CALS.TXT
in a folder labeled “SYS” on the PC Card for the
Legacy 6000.
The calibration table is shown providing nominal calibration numbers for a granular
system that employs Gate Height ranging from 1 to 12 inches. A valid entry must
havethreeeldsseparatedbysquarebrackets.Withinthebrackettheremust be
sometext[GATEHEIGHT][1INCH][1406].TheCalibrationIdentieris thetable
nameorlabelwhenloadingthetableintheLegacy6000. The Cal # Denition
denesthecalibrationnumbertoit.Thecalibrationnumbermust be greater than
zero and the units must relate to those selected during Channel Setup. For exam-
ple; if sensor units are lbs/ac and the Application is type ‘Granular’, the Calibration
# must be in pulses/cubic foot.
Zobrazit stránku 153

Komentáře k této Příručce

Žádné komentáře